AEREON's Cyclone Series Air-assisted flares are comprised of two risers (waste gas and air) and a blower system that provides supplemental combustion air. Air is fed by the blower into the air riser, to eventually combine with the process gas, which passes through its own secondary riser and is distributed at the flare tip through a proprietary AEREON Starfire burner tip. Upon mixing at the flare tip, the high-pressure air flow causes turbulence in the waste gas stream, improving mixing, and ultimately combustion efficiency. These flares generally dispose of heavier waste gases and/or gases with low supply pressures, which have a greater tendency to smoke. These flares will provide smokeless combustion and be Quad O and 40 CFR 60.18 compliant (>98% VOC Destruction Efficiency) with infinite turndown performance. Standard with retractable pilot systems for ease of maintenance, and supplied with guywire supports allowing for rapid onsite installation. Available in 3 in. (gas riser) x 20 ft. to 8 in. (gas riser) x 40 ft. standard sizes that will handle from 0.35 to 4.33 MMSCFD of gas flow at typical conditions (* Flows may be higher depending on available supply pressure and actual gas composition. Please ask your AEREON representative to confirm exact flow rates possible for your application). A new Cyclone HCVL (High Capacity Value Line) at 6, 8 and 10 inch diameters is also available for those that desire a simpler and lower cost tip design that removes the proprietary AEREON Starfire burner tip in lieu of a concentric riser design that promotes mixing and smokeless combustion.